This chapter describes Presence Manager (PM) messages. For information on message content and how to use the message, refer to the Introduction.
PM.001 |
Level: UI-ERROR
Short Syntax: PM.001 Fan fan failed.
Long Syntax: PM.001 Cooling fan fan has failed.
Description: A cooling fan has stopped spinning at the minimum RPM required to provide adequate cooling.
PM.002 |
Level: U-INFO
Short Syntax: PM.002 Fan fan up to speed.
Long Syntax: PM.002 Cooling fan fan is up to speed.
Description: A cooling fan which had previously failed is now spinning at the minimum RPM required to provide adequate cooling.
PM.003 |
Level: U-INFO
Short Syntax: PM.003 Pwr Supp power_supply OFF.
Long Syntax: PM.003 Power Supply power_supply is OFF or has failed.
Description: A power supply has been powered-off or has failed.
PM.004 |
Level: U-INFO
Short Syntax: PM.004 Pwr Supp power_supply ON.
Long Syntax: PM.004 Power Supply power_supply is ON.
Description: A power supply has been powered-on.
PM.005 |
Level: U-INFO
Short Syntax: PM.005 Thermal thermal Overtemp.
Long Syntax: PM.005 Thermal Sensor thermal is over-temp.
Description: A thermal sensor reading has exceeded the specified threshold.
PM.006 |
Level: U-INFO
Short Syntax: PM.006 Thermal thermal below thresh.
Long Syntax: PM.006 Thermal Sensor thermal is below warning level.
Description: A thermal sensor reading which had previously exceeded the specified threshold is now below the specified threshold.
PM.007 |
Level: U-INFO
Short Syntax: PM.007 LIC2 at0 at1 - lic_name detected in slot slot.
Long Syntax: PM.007 LIC2 at0 at1 - lic_name detected in slot slot.
Description: A LIC of the type indicated has been detected in the slot indicated.
PM.008 |
Level: U-INFO
Short Syntax: PM.008 LIC2 at0 at1 - lic_name extracted from slot slot.
Long Syntax: PM.008 LIC2 at0 at1 - lic_name extracted from slot slot.
Description: A LIC of the type indicated has been extracted from the slot indicated.
PM.009 |
Level: UE-ERROR
Short Syntax: PM.009 Mechanical Insertion Error, slot slot.
Long Syntax: PM.009 Mechanical Insertion Error in slot slot.
Description: A mechanical insertion error has occurred indicating that the LIC type could not be detected. Re-inserting the LIC is required.
PM.010 |
Level: UE-ERROR
Short Syntax: PM.010 Unknown LIC Type in slot slot.
Long Syntax: PM.010 Unknown LIC Type detected in slot slot.
Description: The LIC type plugged into the slot does not match any known LIC type.
PM.011 |
Level: UE-ERROR
Short Syntax: PM.011 LIC2 at0 at1 - lic_name is not valid in slot slot.
Long Syntax: PM.011 LIC2 at0 at1 - lic_name is not valid in slot slot.
Description: The type of the LIC plugged into the slot is not compatible with a LIC present in an adjacent slot. As a result, the LIC will not be enabled and the "Wrong Slot" indicator will be on.
PM.012 |
Level: UI-ERROR
Short Syntax: PM.012 LIC2 at0 at1 - lic_name in slot slot is defective.
Long Syntax: PM.012 LIC2 at0 at1 - lic_name in slot slot is defective.
Description: The LIC type plugged into the slot is defective.